Don’t let your current diabetes technology hold you back from leveling up!


Upgrade to the MiniMed™ 780G system for $499.
Terms and conditions apply.*


Inquire today
Man and woman holding medtronic insulin pump
MiniMed 780G system

The MiniMed 780G system


Ever accidentally miss a meal dose or underestimate a carb count? Tired of post-meal highs? Let your insulin pump system do the work!

The MiniMed™ 780G system is the only system with Meal Detection™ technology that detects a meal based on the rapid rise of sugar levels and automatically delivers corrections every 5 minutes to help prevent highs.

Upgrade with the Switch2System program

If you currently use an in-warranty insulin pump from another manufacturer, you may be eligible for our Switch2System program when you trade in your current device.

Simply trade in your existing pump and pay an upgrade fee of just $499 to switch to the MiniMed™ 780G system. If it doesn’t work out, no problem! Just return it within 90 days.

Not all insulin pumps are created equal
Compare latest insulin pump systems


Insulin delivery systems MiniMed 780G system with Guardian 4 sensor   Tandem Control IQ with Dexcom G7®   Beta Bionics® iLet with Dexcom G7®
Meal Detection™ technology notices rapid rise of sugar levels
Meal Detection™ technology notices rapid rise of sugar levels icon green check    
Auto correction bolus
Auto correction bolus Every 5 mins
Up to 8% of the TDD
Every 60 mins
Limited to 6 units
Every 5 mins
Max of 3 units
Automated basal delivery every 5 minutes
Automated basal delivery every 5 minutes icon green check icon green check icon green check
Compatible infusion set for up to 7-day wear
Compatible infusion set for up to 7-day wear icon green check    
Flexible glucose target as low as 100 mg/dL
Flexible glucose target as low as 100 mg/dL icon green check    
Max insulin capacity
Max insulin capacity 300 mL 200 mL (Mobi)
300 mL (Tslim)
180 mL

 Up to 8% of the total daily dose delivered over 45 minutes. Comparison chart based on publicly available information.

Here’s what our customers are saying about the system

97%
felt more freedom to eat what they want4

95%
felt more freedom to eat when they want

96%
felt more freedom to live life the way they want to
Here’s what our customers are saying about the system

Ready to level up to the MiniMed 780G system?


Complete the form to learn more from a diabetes therapy consultant. If you have questions, call 888-882-8602 (M-F 9 a.m. - 6 p.m. CT)


       

How can we communicate with you?


Frequently asked questions


Through the Switch2System program, if for any reason you decide not to stay on it, you’ll have 90 days to return the system.

The Switch2System program is eligible for our payment program, allowing you to split up the fee and pay as little as $50/month. A member of our team will be happy to discuss more details with you.

When you decide you want to stay on the MiniMed™ 780G system, then you will be required to send in your competitor pump.

Footnotes
 Taking a bolus 15 – 20 minutes before a meal helps to keep blood sugar levels under control after eating.
Refers to SmartGuard™ feature. Individual results may vary.
†† Refers to auto correct, which provides bolus assistance. Can deliver all auto correction doses automatically without user interaction, feature can be turned on and off.

References

  1. Adults, T1 and parents of children with T1 diabetes < 18 years were surveyed.
  2. Individual results may vary.
  3. dQ&A US Diabetes Patient Panel Report; Customer Overall Satisfaction, n=146; Q4 2023: P.52 (November 2023).
  4. Comparison of MiniMed™ 780G vs 670G. Data on file from Diabetes Effort Metric Survey: Surveyed MM780G IB who switched from MM670G: Survey Results, N=74 2023, EMEA. Individual results may vary.

Switch2System Program Terms and conditions

  • Customers with more than six months remaining on their competitive pump warranty (or 5-year Medicare guideline) are eligible for the Switch2System Program.
  • A $499 payment will be required to use this program. This price includes one (1) insulin pump, one (1) compatible transmitter, one (1) month of consumables and one (1) month of sensors.
  • Customers enrolled in federal, state, or government-funded healthcare plans are excluded from receiving a transmitter and sensors from this program and cannot participate in a payment plan.
  • An ABN will be required to utilize this program for all Medicare customers.
  • Customers may return product that has been shipped as part of this program up to 90 days from the date of shipment.
  • Customers must return their competitor pump or receiver within 90 days. Customers who do not return their pump will be charged $4,500.
  • This program does not extend the warranty period of the replaced pump. The customer’s current pump warranty timeline will not change by purchasing a pump through this program.
  • Customers should verify that their insurance provider will support transitioning to the new pump, as it could affect ongoing coverage of their future pump supplies.
  • Customer agrees to fully and accurately report in submissions to federal healthcare programs all discounts provided by Medtronic and, upon request by the Secretary of the U.S. Department of Health and Human Services or state agency, make available information any information that Medtronic may provide concerning the discount.
  • MiniMed™ pumps have certain labeling restrictions that may exclude certain populations, including age and type of diabetes. We recommend you consult your
  • Healthcare Provider regarding indications for use.
  • A valid prescription will be required to purchase a pump, CGM and supplies. Other restrictions may apply.
  • Medicare customers within a 13-month rental period cannot participate in this program.
  • Customers using Kaiser health plans are excluded from this program.
  • Pricing, terms, and conditions are subject to change at any time and without notice.

Important safety information: MiniMed 780G system with SmartGuard technology with Guardian 4 sensor

The MiniMed 780G system is intended for continuous delivery of basal insulin at selectable rates, and the administration of insulin boluses at selectable amounts for the management of type 1 diabetes mellitus in persons seven years of age and older requiring insulin as well as for the continuous monitoring and trending of glucose levels in the fluid under the skin. The MiniMed 780G system includes SmartGuard technology, which can be programmed to automatically adjust insulin delivery based on the continuous glucose monitoring (CGM) sensor glucose values and can suspend delivery of insulin when the sensor glucose (SG) value falls below or is predicted to fall below predefined threshold values.

The Medtronic MiniMed 780G system consists of the following devices: MiniMed 780G insulin pump, the Guardian 4 transmitter, the Guardian 4 sensor, One-press serter, the Accu-Chek Guide Link blood glucose meter, and the Accu-Chek Guide test strips. The system requires a prescription from a healthcare professional.

The Guardian 4 sensor is intended for use with the MiniMed 780G system and the Guardian 4 transmitter to monitor glucose levels for the management of diabetes. The sensor is intended for single use and requires a prescription. The Guardian 4 sensor is indicated for up to seven days of continuous use.

The Guardian 4 sensor is not intended to be used directly to make therapy adjustments while the MiniMed 780G is operating in manual mode. All therapy adjustments in manual mode should be based on measurements obtained using a blood glucose meter and not on values provided by the Guardian 4 sensor. The Guardian 4 sensor has been studied and is approved for use in patients ages 7 years and older and in the arm insertion site only. Do not use the Guardian 4 sensor in the abdomen or other body sites including the buttocks, due to unknown or different performance that could result in hypoglycemia or hyperglycemia.

WARNING: Do not use the SmartGuard feature for people who require less than 8 units or more than 250 units of total daily insulin per day. A total daily dose of at least 8 units, but no more than 250 units, is required to operate in the SmartGuard feature.

WARNING: Do not use the MiniMed 780G system until appropriate training has been received from a healthcare professional. Training is essential to ensure the safe use of the MiniMed 780G system.

WARNING: Do not use SG values to make treatment decisions, including delivering a bolus, while the pump is in Manual Mode. When the SmartGuard feature is active and you are no longer in Manual Mode, the pump uses an SG value, when available, to calculate a bolus amount. However, if your symptoms do not match the SG value, use a BG meter to confirm the SG value. Failure to confirm glucose levels when your symptoms do not match the SG value can result in the infusion of too much or too little insulin, which may cause hypoglycemia or hyperglycemia.

Pump therapy is not recommended for people whose vision or hearing does not allow for the recognition of pump signals, alerts, or alarms. The safety of the MiniMed 780G system has not been studied in pregnant women, persons with type 2 diabetes, or in persons using other anti-hyperglycemic therapies that do not include insulin. For complete details of the system, including product and important safety information such as indications, contraindications, warnings and precautions associated with system and its components, please consult https://www.medtronicdiabetes.com/important-safety-information#minimed-780g and the appropriate user guide at https://www.medtronicdiabetes.com/download-library