What is #GetItBack?


"It" is that thing – that one thing that’s uniquely yours. That one thing you love but feel like you don’t get to fully enjoy anymore. Or it’s missing because you’re so focused on your diabetes. Maybe that thing is spending time with loved ones or eating your favorite breakfast food. Our customers are discovering they can get some of these things back with the MiniMed™ 780G system.
What will you get back?

I got my love for food back

Daniela, #MedtronicChampion

Carb counting is a useful tool, but it can also have difficulty in regards to your relationship with food. If I don't nail it in the beginning, the MiniMed™ 780G will auto correct for me.”

Daniela, #MedtronicChampion


The MiniMed™ 780G system and its new Meal Detection™ technology* lets Daniela enjoy her favorite foods without spending extra time to be perfect with carb counting. She knows her best guess is good enough and the system will take care of the rest.


Daniela’s story

We got independence back

Alex and Connor, #MedtronicChampion

Before, when I went to a sleepover my parents would text me every 20 minutes to ask what my sugar level was. Now they can just check on their phone.”

Alex and Connor, #MedtronicChampion


Thanks to the MiniMed™ 780G system automatically adjusting insulin delivery,§ Alex and Connor have more independence to live their life. Their parents got peace of mind back, knowing they can check in on their kids if they need to on the MiniMed™ Mobile app.


Alex and Connor’s story

I got my freedom back

Mike, #MedtronicChampion

When I moved over to the MiniMed™ 780G system, I found it was a lot more convenient for my lifestyle. I didn’t have to be as precise with when I ate or be perfect with carb counting.”

Mike, #MedtronicChampion


With the MiniMed™ 780G system auto correcting every 5 minutes, Mike has more confidence knowing he doesn't need to be exact with carb counting or if he occasionally misses a meal dose.*


Mike’s story

Share your #GetItBack story with #MiniMed780G!


1

Complete the form to receive a #GetItBack t-shirt.

Don’t wait! Supplies are limited.
2

Fill in what you got back in blank spot on the t-shirt.

Marker included in the box!
3

Snap a photo or video then share on social media.

Remember to tag @MedtronicDiabetes and use the #GetItBack and #MiniMed780G hashtags.

Request a #GetItBack t-shirt!


Fill in the form and we will send you a no-cost t-shirt and marker to show off what you got back after using the MiniMed™ 780G system.

Eligible customers must be on the MiniMed™ 780G system and reside in the United States. No purchase necessary. Limited time offer, while supplies last.

 
Got back t-shirt



Designed for real life


The MiniMed™ 780G system helps you focus less on diabetes and more on living in the moment.

New Auto correction
If your carb counts aren’t exact or if you occasionally miss a meal dose*, the system automatically delivers a correction dose.

New Personalized glucose targets
The only system with flexible glucose targets as low as 100 mg/dL.

New No fingersticks** with SmartGuard™ technology
The new Guardian™ 4 sensor sends sugar levels to the pump every 5 minutes§ with no fingersticks required when using SmartGuard™ technology.

Self-adjusting technology
The system automatically adjusts insulin delivery all day and night to help prevent highs and lows.§


Learn more

Woman and girl

References
* Taking a bolus 15 – 20 minutes before a meal helps to keep blood sugar levels under control after eating.
† Refers to auto correct, which provides bolus assistance. Can deliver all auto correction doses automatically without user interaction, feature can be turned on and off.
∆ Glucose targets should be set by your healthcare provider.
§ Refers to SmartGuard™ feature. Individual results may vary.
** Fingersticks required in manual mode and to enter SmartGuard™. If symptoms don’t match alerts and readings, use a fingerstick. Refer to user guide. Pivotal trial participants spend avg of > 93% in SmartGuard™.

Important safety information: MiniMed™ 780G system with SmartGuard™ technology with Guardian™ 4 sensor

The MiniMed™ 780G system is intended for continuous delivery of basal insulin at selectable rates, and the administration of insulin boluses at selectable amounts for the management of type 1 diabetes mellitus in persons seven years of age and older requiring insulin as well as for the continuous monitoring and trending of glucose levels in the fluid under the skin. The MiniMed™ 780G system includes SmartGuard™ technology, which can be programmed to automatically adjust insulin delivery based on the continuous glucose monitoring (CGM) sensor glucose values and can suspend delivery of insulin when the sensor glucose (SG) value falls below or is predicted to fall below predefined threshold values.

The Medtronic MiniMed™ 780G system consists of the following devices: MiniMed™ 780G insulin pump, the Guardian™ 4 transmitter, the Guardian™ 4 sensor, One-press serter, the Accu-Chek™ Guide Link blood glucose meter, and the Accu-Chek™ Guide test strips. The system requires a prescription from a healthcare professional.

The Guardian™ 4 sensor is intended for use with the MiniMed™ 780G system and the Guardian 4 transmitter to monitor glucose levels for the management of diabetes. The sensor is intended for single use and requires a prescription. The Guardian™ 4 sensor is indicated for up to seven days of continuous use.

The Guardian™ 4 sensor is not intended to be used directly to make therapy adjustments while the MiniMed™ 780G is operating in manual mode. All therapy adjustments in manual mode should be based on measurements obtained using a blood glucose meter and not on values provided by the Guardian™ 4 sensor. The Guardian™ 4 sensor has been studied and is approved for use in patients ages 7 years and older and in the arm insertion site only. Do not use the Guardian™ 4 sensor in the abdomen or other body sites including the buttocks, due to unknown or different performance that could result in hypoglycemia or hyperglycemia.

WARNING: Do not use the SmartGuard™ feature for people who require less than 8 units or more than 250 units of total daily insulin per day. A total daily dose of at least 8 units, but no more than 250 units, is required to operate in the SmartGuard™ feature.

WARNING: Do not use the MiniMed™ 780G system until appropriate training has been received from a healthcare professional. Training is essential to ensure the safe use of the MiniMed™ 780G system.

WARNING: Do not use SG values to make treatment decisions, including delivering a bolus, while the pump is in Manual Mode. When the SmartGuard™ feature is active and you are no longer in Manual Mode, the pump uses an SG value, when available, to calculate a bolus amount. However, if your symptoms do not match the SG value, use a BG meter to confirm the SG value. Failure to confirm glucose levels when your symptoms do not match the SG value can result in the infusion of too much or too little insulin, which may cause hypoglycemia or hyperglycemia.

Pump therapy is not recommended for people whose vision or hearing does not allow for the recognition of pump signals, alerts, or alarms. The safety of the MiniMed™ 780G system has not been studied in pregnant women, persons with type 2 diabetes, or in persons using other anti-hyperglycemic therapies that do not include insulin. For complete details of the system, including product and important safety information such as indications, contraindications, warnings and precautions associated with system and its components, please consult https://www.medtronicdiabetes.com/important-safety-information#minimed-780g and the appropriate user guide at https://www.medtronicdiabetes.com/download-library